Hot take: techs keep pulling the fridge out to clean the coils when the front kick plate is the real problem
I fixed a Whirlpool side by side in Akron yesterday that had two other techs out before me, and both of them pulled the whole unit out to vacuum the rear coils. The condenser on that model sits behind the front kick plate, and the plate was packed solid with dog hair, maybe a quarter inch thick, so the compressor was baking itself. I popped four screws, brushed it out with a coil brush, and the box was back to temp in about 3 hours instead of the 8 they were fighting. I'm not saying rear coils never need it, but on these front breather models you're wasting a pull. Has anyone else been seeing this on the newer side by sides?
Four screws and a coil brush versus yanking a whole fridge out and fighting it back in, and these guys picked the hard way twice? Lmao that Akron call was basically a paid vacation compared to theirs. The kick plate on those front breather Whirlpools turns into a dog hair brick and nobody even looks at it. Half the "bad compressor" calls I hear about are just a clogged front plate choking the thing to death. Two techs and eight hours for a quarter inch of fur, that's a rough day for everybody but you.