Warning: I was terminating coax wrong for 2 months until a callback showed me
Had a customer in Mesa call back twice on a drop I ran back in March. I kept blaming the modem, but when I finally pulled the wall plate the stinger was too long and bent over inside the port, which I had been doing on every single termination because nobody showed me how to set the tool depth. My trainer looked at it and said "that's not a stinger, that's a paperclip." Now I check every one with the gauge before it goes in the wall, and I've had zero callbacks on those drops since. Curious how many of you learned this the hard way too, or was it just me?